Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 194
Filtrar
1.
Diabetes Technol Ther ; 26(3): 190-197, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38444313

RESUMO

Aim: To assess the real-world performance of MiniMed™ 780G for Australians with type 1 diabetes (T1D) following advanced hybrid closed loop (AHCL) activation and to evaluate the effect of changing from MiniMed 670/770G to 780G. Methods: We analyzed deidentified Carelink™ continuous glucose monitoring (CGM) data from Australian users from January 2020 to December 2022, including the proportion attaining three major consensus targets: Glucose management indicator (GMI <7.0%), time in range (TIR 70-180 mg/dL >70%), and time below range (TBR 70 mg/dL <4%). Results: Comparing 670/770G users (n = 5676) for mean ± standard deviation 364 ± 244 days with 780G users (n = 3566) for 146 ± 145 days, the latter achieved a higher TIR (72.6% ± 10.6% vs. 67.3% ± 11.4%; P < 0.001), lower time above range (TAR) (25.5% ± 10.9% vs. 30.6% ± 11.7%; P < 0.001), and lower GMI (6.9% ± 0.4% vs. 7.2% ± 0.4%; P < 0.001) without compromising TBR (1.9% ± 1.8% vs. 2.0% ± 1.8%; P = 0.0015). Of 1051 670/770G users transitioning to 780G, TIR increased (70.0% ± 10.7% to 74.0% ± 10.2%; P < 0.001), TAR decreased (28.1% ± 10.9% to 24.0% ± 10.7%; P < 0.001), and TBR was unchanged. The percentage of users attaining all three CGM targets was higher in 780G users (50.1% vs. 29.5%; P < 0.001). CGM metrics were stable at 12 months post-transition. Conclusion: Real-world data from Australia shows that a higher proportion of MiniMed 780G users meet clinical targets for CGM consensus metrics compared to MiniMed 670/770G users and glucose control was sustained over 12 months.


Assuntos
População Australasiana , Automonitorização da Glicemia , Insulina , Humanos , Austrália , Glicemia , Insulina/uso terapêutico , Insulina Regular Humana
2.
Hosp Pharm ; 59(2): 228-233, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38450349

RESUMO

Purpose: Critical care pharmacists are considered essential members of the healthcare team; however, justification and recruitment of new positions, especially in the evening or weekend shifts, remains a significant challenge. The purpose of this study was to investigate the number of interventions, type of interventions, and associated cost savings with the addition of 1 board certified critical care clinical pharmacist to evening shift. Methods: This was a prospective collection and characterization of 1 evening shift critical care pharmacist's clinical interventions over a 12-week period. Interventions were collected and categorized daily from 13:00 to 22:00 Monday through Friday. After collection was complete, cost savings estimates were calculated using pharmacy wholesaler acquisition cost. Results: Interventions were collected on 52 of 60 weekdays. A total of 510 interventions were collected with an average of 9.8 interventions accepted per day. The most common interventions included transitions of care, medication dose adjustment, and antibiotic de-escalation and the highest proportion of interventions occurred in the medical intensive care unit. An estimated associated cost avoidance of $66 537.80 was calculated for an average of $1279.57 saved per day. Additionally, 22 (4.1%) of interventions were considered high yield interventions upon independent review by 2 pharmacists. Conclusion: The addition of 1 board-certified critical care pharmacist to evening shift resulted in multiple interventions across several categories and a significant cost avoidance when calculated using conservative measures.

3.
Diabetes Care ; 47(4): 707-711, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38324670

RESUMO

OBJECTIVE: Technology use in type 1 diabetes (T1D) is impacted by socioeconomic status (SES). This analysis explored relationships between SES, glycemic outcomes, and technology use. RESEARCH DESIGN AND METHODS: A cross-sectional analysis of HbA1c data from 2,822 Australian youth with T1D was undertaken. Residential postcodes were used to assign SES based on the Index of Relative Socio-Economic Disadvantage (IRSD). Linear regression models were used to evaluate associations among IRSD quintile, HbA1c, and management regimen. RESULTS: Insulin pump therapy, continuous glucose monitoring, and their concurrent use were associated with lower mean HbA1c across all IRSD quintiles (P < 0.001). There was no interaction between technology use and IRSD quintile on HbA1c (P = 0.624), reflecting a similar association of lower HbA1c with technology use across all IRSD quintiles. CONCLUSIONS: Technology use was associated with lower HbA1c across all socioeconomic backgrounds. Socioeconomic disadvantage does not preclude glycemic benefits of diabetes technologies, highlighting the need to remove barriers to technology access.


Assuntos
Diabetes Mellitus Tipo 1 , Humanos , Adolescente , Diabetes Mellitus Tipo 1/complicações , Hemoglobinas Glicadas , Estudos Transversais , Automonitorização da Glicemia , Glicemia , Austrália , Classe Social
4.
Transl Stroke Res ; 2024 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-38302738

RESUMO

Hypertension and aging are leading risk factors for stroke and vascular contributions to cognitive impairment and dementia (VCID). Most animal models fail to capture the complex interplay between these pathophysiological processes. In the current study, we examined the development of cognitive impairment in 18-month-old spontaneously hypertensive rats (SHR) before and following ischemic stroke. Sixty SHRs were housed for 18 months with cognitive assessments every 6 months and post-surgery. MRI scans were performed at baseline and throughout the study. On day 3 post-stroke, rats were randomized to receive either angiotensin II type 2 receptor (AT2R) agonist Compound 21 (C21) or plain water for 8 weeks. SHRs demonstrated a progressive cognitive decline and significant MRI abnormalities before stroke. Perioperative mortality within 72 h of stroke was low. Stroke resulted in significant acute brain swelling, chronic brain atrophy, and sustained sensorimotor and behavioral deficits. There was no evidence of anhedonia at week 8. C21 enhanced sensorimotor recovery and ischemic lesion resolution at week 8. SHRs represent a clinically relevant animal model to study aging and stroke-associated VCID. This study underscores the importance of translational disease modeling and provides evidence that modulation of the AT2R signaling via C21 may be a useful therapeutic option to improve sensorimotor and cognitive outcomes even in aged animals.

5.
J Diabetes Sci Technol ; : 19322968241231307, 2024 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-38372246

RESUMO

BACKGROUND: Glycemia risk index (GRI) is a novel composite metric assessing overall glycemic risk, accounting for both hypoglycemia and hyperglycemia and weighted toward extremes. Data assessing GRI as an outcome measure in closed-loop studies and its relation with conventional key continuous glucose monitoring (CGM) metrics are limited. METHODS: A post hoc analysis was performed to evaluate the sensitivity of GRI in assessing glycemic quality in adults with type 1 diabetes randomized to 26 weeks hybrid closed-loop (HCL) or manual insulin delivery (control). The primary outcome was GRI comparing HCL with control. Comparisons were made with changes in other CGM metrics including time in range (TIR), time above range (TAR), time below range (TBR), and glycemic variability (standard deviation [SD] and coefficient of variation [CV]). RESULTS: GRI with HCL (N = 61) compared with control (N = 59) was significantly lower (mean [SD] 33.5 [11.7] vs 56.1 [14.4], respectively; mean difference -22.8 [-27.2, -18.3], P = .001). The mean increase in TIR was +14.8 (11.0, 18.5)%. GRI negatively correlated with TIR for combined arms (r = -.954; P = .001), and positively with TAR >250 mg/dL (r = .901; P = .001), TBR < 54 mg/dL (r = .416; P = .001), and glycemic variability (SD [r = .916] and CV [r = .732]; P = .001 for both). CONCLUSIONS: Twenty-six weeks of HCL improved GRI, in addition to other CGM metrics, compared with standard insulin therapy. The improvement in GRI was proportionally greater than the change in TIR, and GRI correlated with all CGM metrics. We suggest that GRI may be an appropriate primary outcome for closed-loop trials.

6.
J Homosex ; : 1-15, 2024 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-38377333

RESUMO

The aims of this study were to identify Australian mental health practitioners' knowledge of what LGBTQA+ conversion practices are and their perceptions of impacts on survivors. We interviewed 18 mental health workers from a range of clinical modalities who were practicing in Australia. We used reflexive thematic analytic techniques to identify themes that characterized Australian mental health practitioners' knowledge of LGBTQA+ conversion practices and perceptions of the impacts of such practices on survivors. Practitioners' understandings of what constitutes LGBTQA+ conversion practices were varied and derived from a range of sources, and practitioners' perceptions of the impacts that conversion practices had on survivors ranged from undeveloped to nuanced. Generalist and specialist practitioners provided vastly different responses. We identified the following four themes: (1) inexperienced practitioners' understandings were limited and reliant on stereotypes about conversion practices; (2) specialist practitioners' understandings were refined and match experiences reported by survivors; (3) generalist practitioners emphasized specific and undeveloped negative impacts; (4) specialist practitioners were aware of deeper harms and the need for sustained support. These themes may be translated into strategies to facilitate improved services offered by practitioners, which may assist survivors in managing and coping with the trauma associated with exposure to these practices.

7.
Artigo em Inglês | MEDLINE | ID: mdl-38215208

RESUMO

Advanced hybrid closed-loop (AHCL) therapy with the Medtronic MiniMed™ 780G system improves glycemia; however, the clinical outcomes in younger children remain less established. This pilot study aimed to explore the continuous glucose monitoring (CGM) metrics in very young children on AHCL. Children between 2 and 7 years of age and on insulin pump therapy were recruited. A 2-week phase in manual mode was followed by a 6-week AHCL phase. CGM metrics were analyzed to review glycemic outcomes. Out of 11 participants enrolled [mean (standard deviation [SD]) age 5.3 (0.8) years], 10 completed the study. Time in closed loop was 96.7 (3.9)%. In AHCL, participants had a mean (SD) time in range of 72.6 (7.4)% and spent 3.0 (1.74)% and 0.63 (0.46)% in time <70 and <54 mg/dL, respectively. AHCL is a feasible option for management of young children with type 1 diabetes.

8.
Diabetologia ; 67(2): 392-402, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38010533

RESUMO

AIMS/HYPOTHESIS: Impaired awareness of hypoglycaemia (IAH) in type 1 diabetes may develop through a process referred to as habituation. Consistent with this, a single bout of high intensity interval exercise as a novel stress stimulus improves counterregulatory responses (CRR) to next-day hypoglycaemia, referred to as dishabituation. This longitudinal pilot study investigated whether 4 weeks of high intensity interval training (HIIT) has sustained effects on counterregulatory and symptom responses to hypoglycaemia in adults with type 1 diabetes and IAH. METHODS: HIT4HYPOS was a single-centre, randomised, parallel-group study. Participants were identified using the Scottish Diabetes Research Network (SDRN) and from diabetes outpatient clinics in NHS Tayside, UK. The study took place at the Clinical Research Centre, Ninewells Hospital and Medical School, Dundee, UK. Participants were aged 18-55 years with type 1 diabetes of at least 5 years' duration and HbA1c levels <75 mmol/mol (<9%). They had IAH confirmed by a Gold score ≥4, modified Clarke score ≥4 or Dose Adjustment For Normal Eating [DAFNE] hypoglycaemia awareness rating of 2 or 3, and/or evidence of recurrent hypoglycaemia on flash glucose monitoring. Participants were randomly allocated using a web-based system to either 4 weeks of real-time continuous glucose monitoring (RT-CGM) or RT-CGM+HIIT. Participants and investigators were not masked to group assignment. The HIIT programme was performed for 20 min on a stationary exercise bike three times a week. Hyperinsulinaemic-hypoglycaemic (2.5 mmol/l) clamp studies with assessment of symptoms, hormones and cognitive function were performed at baseline and after 4 weeks of the study intervention. The predefined primary outcome was the difference in hypoglycaemia-induced adrenaline (epinephrine) responses from baseline following RT-CGM or RT-CGM+HIIT. RESULTS: Eighteen participants (nine men and nine women) with type 1 diabetes (median [IQR] duration 27 [18.75-32] years) and IAH were included, with nine participants randomised to each group. Data from all study participants were included in the analysis. During the 4 week intervention there were no significant mean (SEM) differences between RT-CGM and RT-CGM+HIIT in exposure to level 1 (28 [7] vs 22 [4] episodes, p=0.45) or level 2 (9 [3] vs 4 [1] episodes, p=0.29) hypoglycaemia. The CGM-derived mean glucose level, SD of glucose and glucose management indicator (GMI) did not differ between groups. During the hyperinsulinaemic-hypoglycaemic clamp studies, mean (SEM) change from baseline was greater for the noradrenergic responses (RT-CGM vs RT-CGM+HIIT: -988 [447] vs 514 [732] pmol/l, p=0.02) but not the adrenergic responses (-298 [687] vs 1130 [747] pmol/l, p=0.11) in those participants who had undergone RT-CGM+HIIT. There was a benefit of RT-CGM+HIIT for mean (SEM) change from baseline in the glucagon CRR to hypoglycaemia (RT-CGM vs RT-CGM+HIIT: 1 [4] vs 16 [6] ng/l, p=0.01). Consistent with the hormone response, the mean (SEM) symptomatic response to hypoglycaemia (adjusted for baseline) was greater following RT-CGM+HIIT (RT-CGM vs RT-CGM+HIIT: -4 [2] vs 0 [2], p<0.05). CONCLUSIONS/INTERPRETATION: In this pilot clinical trial in people with type 1 diabetes and IAH, we found continuing benefits of HIIT for overall hormonal and symptomatic CRR to subsequent hypoglycaemia. Our findings also suggest that HIIT may improve the glucagon response to insulin-induced hypoglycaemia. TRIAL REGISTRATION: ISRCTN15373978. FUNDING: Sir George Alberti Fellowship from Diabetes UK (CMF) and the Juvenile Diabetes Research Foundation.


Assuntos
Diabetes Mellitus Tipo 1 , Treinamento Intervalado de Alta Intensidade , Hipoglicemia , Adulto , Masculino , Humanos , Feminino , Diabetes Mellitus Tipo 1/tratamento farmacológico , Automonitorização da Glicemia , Glucagon , Projetos Piloto , Glicemia/análise , Hipoglicemia/tratamento farmacológico , Hipoglicemiantes/uso terapêutico , Epinefrina
9.
BMC Med ; 21(1): 506, 2023 12 20.
Artigo em Inglês | MEDLINE | ID: mdl-38124088

RESUMO

BACKGROUND: Given limited data regarding the involvement of disadvantaged groups in paediatric diabetes clinical trials, this study aimed to evaluate the socioeconomic representativeness of participants recruited into a multinational clinical trial in relation to regional and national type 1 diabetes reference populations. METHODS: Retrospective, cross-sectional evaluation of a subset of adolescent type 1 diabetes cardiorenal intervention trial (AdDIT) participants from Australia (n = 144), Canada (n = 312) and the UK (n = 173). Validated national measures of deprivation were used: the Index of Relative Socioeconomic Disadvantage (IRSD) 2016 (Australia), the Material Resources (MR) dimension of the Canadian Marginalisation index 2016 (Canada) and the Index of Multiple Deprivation (IMD) 2015 (UK). Representativeness was assessed by comparing the AdDIT cohort's distribution of deprivation quintiles with that of the local paediatric type 1 diabetes population (regional), and the broader type 1 diabetes population for which the trial's intervention was targeted (national). RESULTS: Recruited study cohorts from each country had higher proportions of participants with higher SES, and significant underrepresentation of lower SES, in relation to their national references. The socioeconomic make-up in Australia mirrored that of the regional population (p = 0.99). For Canada, the 2nd least deprived (p = 0.001) and the most deprived quintiles (p < 0.001) were over- and under-represented relative to the regional reference, while the UK featured higher regional and national SES bias with over-representation and under-representation from the least-deprived and most-deprived quintiles (p < 0.0001). CONCLUSIONS: Significant national differences in trial participation of low SES participants were observed, highlighting limitations in access to clinical research and the importance of reporting sociodemographic representation in diabetes clinical trials. TRIAL REGISTRATION: NCT01581476. Registered on 20 April 2012.


Assuntos
Diabetes Mellitus Tipo 1 , Adolescente , Humanos , Austrália/epidemiologia , Canadá/epidemiologia , Ensaios Clínicos como Assunto , Estudos Transversais , Diabetes Mellitus Tipo 1/epidemiologia , Diabetes Mellitus Tipo 1/terapia , Estudos Retrospectivos , Fatores Socioeconômicos
10.
J Endocr Soc ; 7(12): bvad128, 2023 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-37942293

RESUMO

Context: It is unclear whether immersion in cool water, typical of many beaches, increases the concentration of blood glucose in individuals with type 1 diabetes mellitus (T1DM). Objective: To test the hypothesis in individuals with T1DM that immersion neck-deep in cool water (COOL) causes an increase in blood glucose concentration, but not exposure to thermoneutral water (THERMO) or thermoneutral air. Methods: Eight overnight-fasted participants with T1DM were exposed for 60 minutes on separate days to 3 experimental conditions: cool water (COOL, 23 °C); thermoneutral water (THERMO, 33.5 °C); or thermoneutral air (24 °C). They then recovered for 60 minutes on land at 24 °C. At time intervals, we measured: blood glucose and plasma insulin concentration, rate of carbohydrate and fat oxidation, skin and core temperature, subcutaneous blood flow, and shivering via electromyography. Results: There was no change in blood glucose concentration during the 3 experimental conditions (P > .05). During recovery after COOL, blood glucose increased (P < .05) but did not change in the other 2 conditions. The rate of carbohydrate oxidation during and early after COOL was higher than in the other 2 conditions (P < .05), and COOL led to a decrease in subcutaneous blood flow and the concentration of plasma insulin (P < .05). Conclusion: Cool or thermoneutral neck-deep immersion in water does not cause a change in the concentration of blood glucose in people with T1DM, but on-land recovery from COOL causes an increase in blood glucose that may be due, at least in part, to the accompanying decrease in plasma insulin.

11.
Front Endocrinol (Lausanne) ; 14: 1178958, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37670884

RESUMO

Background: Technology use, including continuous glucose monitoring (CGM) and insulin pump therapy, is associated with improved outcomes in youth with type 1 diabetes (T1D). In 2017 CGM was universally funded for youth with T1D in Australia. In contrast, pump access is primarily accessed through private health insurance, self-funding or philanthropy. The study aim was to investigate the use of diabetes technology across different socioeconomic groups in Australian youth with T1D, in the setting of two contrasting funding models. Methods: A cross-sectional evaluation of 4957 youth with T1D aged <18 years in the national registry was performed to determine technology use. The Index of Relative Socio-Economic Disadvantage (IRSD) derived from Australian census data is an area-based measure of socioeconomic status (SES). Lower quintiles represent greater disadvantage. IRSD based on most recent postcode of residence was used as a marker of SES. A multivariable generalised linear model adjusting for age, diabetes duration, sex, remoteness classification, and location within Australia was used to determine the association between SES and device use. Results: CGM use was lower in IRSD quintile 1 in comparison to quintiles 2 to 5 (p<0.001) where uptake across the quintiles was similar. A higher percentage of pump use was observed in the least disadvantaged IRSD quintiles. Compared to the most disadvantaged quintile 1, pump use progressively increased by 16% (95% CI: 4% to 31%) in quintile 2, 19% (6% to 33%) in quintile 3, 35% (21% to 50%) in quintile 4 and 51% (36% to 67%) in the least disadvantaged quintile 5. Conclusion: In this large national dataset, use of diabetes technologies was found to differ across socioeconomic groups. For nationally subsidised CGM, use was similar across socioeconomic groups with the exception of the most disadvantaged quintile, an important finding requiring further investigation into barriers to CGM use within a nationally subsidised model. User pays funding models for pump therapy result in lower use with socioeconomic disadvantage, highlighting inequities in this funding approach. For the full benefits of diabetes technology to be realised, equitable access to pump therapy needs to be a health policy priority.


Assuntos
Diabetes Mellitus Tipo 1 , Adolescente , Humanos , Automonitorização da Glicemia , Estudos Transversais , Austrália , Glicemia , Tecnologia
12.
BMC Health Serv Res ; 23(1): 779, 2023 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-37474959

RESUMO

BACKGROUND: Managing the care regimen for Type 1 Diabetes is challenging for emerging adults, as they take on greater responsibility for self-management. A diverse range of models of care have been implemented to improve safety and quality of care during transition between paediatric and adult services. However, evidence about acceptability and effectiveness of these is limited. Our aim was to synthesise the evidence for transition models and their components, examine the health related and psychosocial outcomes, and to identify determinants associated with the implementation of person-centred models of transition care. METHOD: We searched Medline, CINAHL, EMBASE and Scopus. Peer reviewed empirical studies that focused on T1D models of care published from 2010 to 2021 in English, reporting experimental, qualitative, mixed methods, and observational studies were included. RESULTS: Fourteen studies reported on health and psychosocial outcomes, and engagement with healthcare. Three key models of care emerged: structured transition education programs (6 studies), multidisciplinary team transition support (5 studies) and telehealth/virtual care (3 studies). Compared with usual practice, three of the six structured transition education programs led to improvements in maintenance of glycaemic control, psychological well-being, and engagement with health services. Four MDT transition care models reported improved health outcomes, and improved engagement with health services, however, three studies reported no benefit. Reduced diabetes related stress and increased patient satisfaction were reported by two studies, but three reported no benefit. Telehealth and virtual group appointments improved adherence to self-management and reduced diabetes distress but did not change health outcomes. CONCLUSIONS: Although some health and psychosocial benefits are reported, the results were mixed. No studies reported on T1D transition model implementation outcomes such as acceptability, adoption, and appropriateness among clinicians or managers implementing these models. This gap needs to be addressed to support future adoption of successful models.


Assuntos
Diabetes Mellitus Tipo 1 , Transição para Assistência do Adulto , Adulto , Criança , Humanos , Diabetes Mellitus Tipo 1/terapia , Diabetes Mellitus Tipo 1/psicologia
13.
Life (Basel) ; 13(6)2023 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-37374057

RESUMO

BACKGROUND: Sustained microglial activation contributes to the development of post-stroke cognitive impairment (PSCI). Compound 21 (C21), an angiotensin II type 2 receptor agonist, has shown some neurovascular protection after stroke. This study aimed to investigate the direct anti-inflammatory effects of C21 on macrophages, as well as brain innate immune cells. METHODS: Murine microglial cell line (C8-B4) and RAW 264.7 macrophages were exposed to lipopolysaccharide (LPS) and co-treated with C21. Pro-inflammatory mediators were assessed via RT-qPCR and ELISA. Cellular reactive oxygen species (ROS) were evaluated via CellROXGreen staining, and nitrate production was assessed using Griess assay. RESULTS: C21 suppressed LPS-induced inflammation and ROS generation in both cells. In microglia, C21 blunted LPS-induced mRNA expression of IL-1ß, IL-12b, COX-1, iNOS, and IL-6. A similar pattern was observed in macrophages, where C21 suppressed LPS-induced IL-1ß, TNF-α, and CXCL1 expression. These anti-inflammatory effects in microglia and macrophages were associated with increased neuroprotective gene expression, including GDNF and BDNF, in a dose-dependent manner. CONCLUSIONS: Our findings suggest a protective effect of C21 against the inflammatory response, in both macrophages and microglia, via suppression of the release of pro-inflammatory cytokines/chemokines and the generation of ROS while stimulating the production of neurotrophic factors.

14.
Respir Res ; 24(1): 166, 2023 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-37349704

RESUMO

BACKGROUND: Matrix metalloproteinase-3 (MMP-3) is a proteolytic enzyme involved in acute respiratory distress syndrome (ARDS) pathophysiology that may serve as a lung-specific biomarker in ARDS. METHODS: This study was a secondary biomarker analysis of a subset of Albuterol for the Treatment of Acute Lung Injury (ALTA) trial patients to determine the prognostic value of MMP-3. Plasma sample MMP-3 was measured by enzyme-linked immunosorbent assay. The primary outcome was the area under the receiver operating characteristic (AUROC) of MMP-3 at day 3 for the prediction of 90-day mortality. RESULTS: A total of 100 unique patient samples were evaluated and the AUROC analysis of day three MMP-3 showed an AUROC of 0.77 for the prediction of 90-day mortality (95% confidence interval: 0.67-0.87), corresponding to a sensitivity of 92% and specificity of 63% and an optimal cutoff value of 18.4 ng/mL. Patients in the high MMP-3 group (≥ 18.4 ng/mL) showed higher mortality compared to the non-elevated MMP-3 group (< 18.4 ng/mL) (47% vs. 4%, p < 0.001). A positive difference in day zero and day three MMP-3 concentration was predictive of mortality with an AUROC of 0.74 correlating to 73% sensitivity, 81% specificity, and an optimal cutoff value of + 9.5 ng/mL. CONCLUSIONS: Day three MMP-3 concentration and difference in day zero and three MMP-3 concentrations demonstrated acceptable AUROCs for predicting 90-day mortality with a cut-point of 18.4 ng/mL and + 9.5 ng/mL, respectively. These results suggest a prognostic role of MMP-3 in ARDS.


Assuntos
Metaloproteinase 3 da Matriz , Síndrome do Desconforto Respiratório , Humanos , Pulmão , Prognóstico , Biomarcadores
15.
Front Endocrinol (Lausanne) ; 14: 1173559, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37361523

RESUMO

Introduction: In Australia, access to insulin pump therapy for children with type 1 diabetes (T1D) is predominantly restricted to families with private health insurance. In an attempt to improve equity, additional subsidised pathways exist which provide pumps to families with reduced financial resources. We aimed to describe the outcomes and experiences of families with children commenced on pumps through these subsidised pathways in Western Australia (WA). Methods: Children with T1D in WA who did not have private health insurance and received pumps from the subsidised pump programs between January 2016 and December 2020 were included. Study 1 was designed to review glycaemic outcome. A retrospective analysis of HbA1c was conducted in the whole cohort and in children who commenced pump after the first year of diagnosis to exclude the impact of the partial clinical remission phase following diagnosis. HbA1c at baseline, and six, 12, 18 and 24 months after pump initiation were collected. Study 2 was designed to review experiences of families commenced on pumps through subsidised pathway. A questionnaire designed by the clinical team was distributed to parents via an online secure platform to capture their experiences. Results: Of the 61 children with mean (SD) age 9.0 (4.9) years who commenced pump therapy through subsidised pump programs, 34 children commenced pump therapy after one year of diagnosis of T1D. The median (IQR) HbA1c (%) in 34 children at baseline was 8.3 (1.3), with no statistically significant change from baseline at six months [7.9 (1.4)], 12 months [8.0 (1.5)], 18 months [8.0 (1.3)] or 24 months [8.0 (1.3)]. The questionnaire response rate was 56%. 83% reported intention to continue pump therapy, however 58% of these families did not have avenue to acquire private health insurance. Families expressed inability to procure private health insurance due to low income and unreliable employment and remained largely unsure about the pathway to obtain the next pump. Discussion: Children with T1D who commenced insulin pump therapy on subsidised pathways maintained glycaemic control for two years, and families favored pumps as a management option. However, financial limitations persist as a significant barrier to procure and continue pump therapy. Pathways for access need to be assessed and advocated.


Assuntos
Diabetes Mellitus Tipo 1 , Humanos , Criança , Diabetes Mellitus Tipo 1/tratamento farmacológico , Insulina/uso terapêutico , Hemoglobinas Glicadas , Estudos Retrospectivos , Austrália Ocidental/epidemiologia
16.
Genes (Basel) ; 14(6)2023 05 31.
Artigo em Inglês | MEDLINE | ID: mdl-37372384

RESUMO

A 28-year-old man with congenital hypogonadotropic hypogonadism (CHH) was found to be heterozygous for the GNRH1 p.R31C mutation, reported in the literature as pathogenic and dominant. The same mutation was found in his son at birth, but the testing of the infant at 64 days confirmed the hormonal changes associated with minipuberty. This led to further genetic sequencing of the patient and his son, which found a second variant, AMHR2 p.G445_L453del, in the heterozygous form, reported as pathogenic in the patient but not in his son. This suggests a digenic cause of the patient's CHH. Together, these mutations are postulated to contribute to CHH by the lack of anti-Müllerian hormone (AMH) signalling, leading to the impaired migration of gonadotrophin releasing hormone (GnRH) neurons, the lack of the AMH effect on GnRH secretion, and altered GnRH decapeptide with reduced binding to GnRH receptors. This led us to the conclusion that the observed GNRH1 mutation in the heterozygous state is not certain to be dominant or, at least, exhibits incomplete penetrance and variable expressivity. This report also emphasises the opportunity afforded by the time window of minipuberty in assessing the inherited genetic disorders of hypothalamic function.


Assuntos
Hormônio Liberador de Gonadotropina , Hipogonadismo , Adulto , Humanos , Lactente , Masculino , Hormônio Liberador de Gonadotropina/genética , Hormônio Liberador de Gonadotropina/metabolismo , Heterozigoto , Hipogonadismo/genética , Mutação , Neurônios/metabolismo , Proteínas Serina-Treonina Quinases/genética
17.
Diabetes Technol Ther ; 25(8): 549-553, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37053526

RESUMO

Continuous glucose monitoring (CGM) systems are used in therapeutic decisions for diabetes management, however, the impact of body composition on CGM accuracy is not known. Body composition variables (body mass index [BMI], midarm circumference, percentage fat, and impedance) were collected in an observational study designed to determine the accuracy of an investigational Medtronic Guardian™ sensor 3. Seven days of sensor glucose data were analyzed from 112 participants >7 years of age with mean BMI Z score 0.48 (<18 years) and BMI 26.7 kg/m2 (≥18 years). The outcome was the absolute relative difference between the sensor and blood glucose readings. Data were analyzed using generalized estimating equations to account for correlation between repeated measures. No statistically significant associations between measures of body composition and device accuracy were found. Body composition does not have a meaningful impact on the accuracy of CGM systems.


Assuntos
Glicemia , Diabetes Mellitus Tipo 1 , Humanos , Adolescente , Diabetes Mellitus Tipo 1/tratamento farmacológico , Automonitorização da Glicemia , Reprodutibilidade dos Testes , Calibragem
18.
Diabetes Technol Ther ; 25(5): 356-362, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36802246

RESUMO

Objective: To explore the impact of missing data on the accuracy of continuous glucose monitoring (CGM) metrics collected for a 2-week period in a clinical trial. Research Design and Methods: Simulations were conducted to examine the effect of various patterns of missingness on the accuracy of CGM metrics as compared with a "complete" data set. The proportion of missing data, the "block size" in which the data were missing, and the missing mechanism were modified for each "scenario." The degree of agreement between simulated and "true" glycemic measures under each scenario was presented as R2. Results: Under all missing patterns, R2 declined as the proportion of missing data increased, however, as the "block size" of missing data increased, the percentage of missing data had a more pronounced effect on the agreement between measures. For a 14-day CGM data set to be considered representative for percentage time in range (%TIR), at least 70% of CGM data should be available over at least 10 days (R2 > 0.9). Skewed outcome measures, such as percentage time below range and coefficient of variation, were more affected by missing data than the less skewed measures (%TIR, percentage time above range, mean glucose). Conclusions: Both the degree and pattern of missing data impact upon the accuracy of recommended CGM-derived glycemic measures. In planning research, an understanding of patterns of missing data in the study population is required to gauge the likely effects of missing data on outcome accuracy. Trial registration number: Australian New Zealand Clinic Trials Registry ACTRN12616000753459.


Assuntos
Glicemia , Diabetes Mellitus Tipo 1 , Humanos , Glucose , Automonitorização da Glicemia , Benchmarking , Austrália
19.
Nutrients ; 15(3)2023 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-36771250

RESUMO

Dietary protein causes dose-dependent hyperglycemia in individuals with type 1 diabetes (T1D). This study investigated the effect of consuming 50 g of protein on overnight blood glucose levels (BGLs) following late-afternoon moderate-intensity exercise. Six participants (3M:3F) with T1D, HbA1c 7.5 ± 0.8% (58.0 ± 8.7 mmol/mol) and aged 20.2 ± 3.1 years exercised for 45 min at 1600 h and consumed a protein drink or water alone at 2000 h, on two separate days. A basal insulin euglycemic clamp was employed to measure the mean glucose infusion rates (m-GIR) required to maintain euglycemia on both nights. The m-GIR on the protein and water nights during the hypoglycemia risk period and overnight were 0.27 ± 043 vs. 1.60 ± 0.66 mg/kg/min (p = 0.028, r = 0.63) and 0.51 ± 0.16 vs. 1.34 ± 0.71 mg/kg/min (p = 0.028, r = 0.63), respectively. Despite ceasing intravenous glucose infusion on the protein night, the BGLs peaked at 9.6 ± 1.6 mmol/L, with a hypoglycemia risk period mean of 7.8 ± 1.5 mmol/L compared to 5.9 ± 0.4 mmol/L (p = 0.028) on the water night. The mean plasma glucagon levels were 51.5 ± 14.1 and 27.2 ± 10.1 ng/L (p = 0.028) on the protein and water night, respectively. This suggests that an intake of protein is effective at reducing the post-exercise hypoglycemia risk, potentially via a glucagon-mediated stimulation of glucose production. However, 50 g of protein may be excessive for maintaining euglycemia.


Assuntos
Diabetes Mellitus Tipo 1 , Exercício Físico , Hipoglicemia , Adolescente , Humanos , Glicemia/metabolismo , Ingestão de Alimentos , Glucagon , Glucose , Hipoglicemia/prevenção & controle , Insulina , Projetos Piloto , Adulto Jovem , Exercício Físico/efeitos adversos
20.
Intern Med J ; 53(1): 61-67, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-34142758

RESUMO

BACKGROUND: The goal of therapy in type 1 diabetes (T1D) is to achieve optimal glycaemic targets and reduce complications. Robust data representing glycaemic outcomes across the lifespan are lacking in Australasia. AIMS: To examine contemporary glycaemic outcomes and rate of use of diabetes technologies in Australasian people with T1D. METHODS: Cross-sectional analysis of de-identified data from 18 diabetes centres maintained in the Australasian Diabetes Data Network registry during 2019. Glycaemia was measured using glycated haemoglobin (HbA1c). The proportion of people with T1D achieving the international HbA1c target of <53 mmol/mol (7%) was calculated. Rates of continuous subcutaneous insulin infusion (CSII) and continuous glucose monitoring (CGM) use were determined. RESULTS: A total of 7988 individuals with T1D with 30 575 visits were recorded in the registry. The median (interquartile range) age was 15.3 (10.0) years and diabetes duration was 5.7 (9.4) years with 49% on multiple daily injections (MDI) and 36% on CSII. The mean HbA1c for the whole cohort was 66 mmol/mol (8.2%). HbA1c increased with age, from 60 mmol/mol (7.6%) in children <10 years, increasing during adolescence and peaking at 73 mmol/mol (8.8%) in the 20-25 years age group. The HbA1c target of <53 mmol/mol (7%) was met in 18% of children and 13% of adults. HbA1c was lower on CSII as compared with those on MDI (P < 0.0001). CONCLUSIONS: Only a minority of children and adults achieve the recommended glycaemic goals despite access to specialist care in major diabetes centres. There is a need to identify factors that improve glycaemic outcomes.


Assuntos
Diabetes Mellitus Tipo 1 , Adolescente , Humanos , Criança , Adulto , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/epidemiologia , Hipoglicemiantes/uso terapêutico , Hemoglobinas Glicadas , Automonitorização da Glicemia , Estudos Transversais , Glicemia , Sistemas de Infusão de Insulina , Insulina/uso terapêutico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...